UV-VIS Ascorbyl Glucoside Content Measurement

  • Product Code: 35472
This spectrophotometric method is used to quantify Ascorbyl Glucoside in a given sample. Ascorbyl Glucoside is a vitamin C derivative commonly used in skincare and pharmaceutical products for its stable, skin-benefiting properties. Accurately determining its concentration ensures product quality, efficacy, and compliance with formulation specifications. The assay uses UV-Vis spectrophotometry at 260 nm, where Ascorbyl Glucoside shows a strong absorbance. A calibration curve over a linear range of 0–35 µg/mL provides a reliable relationship between absorbance and concentration. By measuring sample absorbance under the same conditions and applying the linear equation (y = 0.0402x + 0.0436), the method allows precise calculation of Ascorbyl Glucoside content.
฿2,990.00

label ชื่อตัวอย่าง

info Please enter each sample name you want included for testing

assignment คำแนะนำ

info โปรดระบุข้อกำหนดหรือเงื่อนไขเฉพาะสำหรับการทดสอบ

insert_drive_file Lab Report

Select a tab and click View to open the report.

timeline ขั้นตอนการให้บริการ

ขั้นตอน ขั้นตอน ผลลัพธ์ที่คาดหวัง
1

Prepare the...

check_circle_outline

A clear 1000 µg/mL Ascorbyl Glucoside standard stock solution.

2

Prepare Calibration...

check_circle_outline

A series of standard solutions at known concentrations for calibration.

3

Determine Maximum...

check_circle_outline

Confirmation that 260 nm is the wavelength of maximum absorbance for Ascorbyl Glucoside.

4

Measure Calibration...

check_circle_outline

A set of absorbance readings to construct the calibration curve.

5

Construct Calibration...

check_circle_outline

A validated linear equation and correlation coefficient confirming the method’s linear range..

6

Prepare the...

check_circle_outline

A homogenous sample solution suitable for measurement.

7

Measure Sample...

check_circle_outline

An accurate absorbance value for the sample, comparable to the calibration standards.

8

Calculate Sample...

check_circle_outline

Determination of the Ascorbyl Glucoside content (µg/mL) in the test sample.

9

Finalize and...

check_circle_outline

A completed analysis with documented data and final reported value of Ascorbyl Glucoside content.

คุณจะได้รับรายงานสำหรับ Ascorbyl Glucoside Concentration (ug/ml) ฟิลด์เมื่อเราให้บริการนี้

ตะกร้า

ไม่มีสินค้า

Subtotal: 0.00
รวมทั้งสิ้น 0.00 THB
UV-VIS Ascorbyl Glucoside Content Measurement

UV-VIS Ascorbyl Glucoside Content Measurement

Mechanism -
Appearance -
Longevity -
Strength -
Storage -
Shelf Life -
Allergen(s) -
Dosage (Range) -
Dosage (Per Day) -
Mix Method -
Heat Resistance -
Stable in pH range -
Solubility -
Product Types -
INCI -
Service Steps
Step Procedure Expected Result
1

Prepare the...

A clear 1000 µg/mL Ascorbyl Glucoside standard stock solution.

2

Prepare Calibration...

A series of standard solutions at known concentrations for calibration.

3

Determine Maximum...

Confirmation that 260 nm is the wavelength of maximum absorbance for Ascorbyl Glucoside.

4

Measure Calibration...

A set of absorbance readings to construct the calibration curve.

5

Construct Calibration...

A validated linear equation and correlation coefficient confirming the method’s linear range..

6

Prepare the...

A homogenous sample solution suitable for measurement.

7

Measure Sample...

An accurate absorbance value for the sample, comparable to the calibration standards.

8

Calculate Sample...

Determination of the Ascorbyl Glucoside content (µg/mL) in the test sample.

9

Finalize and...

A completed analysis with documented data and final reported value of Ascorbyl Glucoside content.