UV-VIS Resveratrol Content Measurement

  • Product Code: 32525
Resveratrol is a polyphenolic compound which has antioxidant properties and potential health benefits and found in various plant-based foods such as grapes, berries, and peanuts. Determination of the resveratrol content is an analytical technique to quantify the amount of resveratrol present in an unknown sample.
฿2,990.00

label Sample Names

info Please enter each sample name you want included for testing

assignment Instructions

info Please include any specific requirements or conditions for testing

description Sample Requirement

Measuring the resveratrol content in a sample using UV-Vis (Ultraviolet-Visible) spectroscopy is a common and reliable analytical technique. Resveratrol is a natural compound found in grapes, red wine, and some other plants, known for its potential health benefits. UV-Vis spectroscopy works based on the principle that molecules absorb light at specific wavelengths, and this absorption can be used to quantify the concentration of a substance in a sample.

Materials and Equipment:

UV-Vis spectrophotometer
Resveratrol standard solution (of known concentration)
Sample containing resveratrol
Appropriate cuvettes or glass vials
Solvents (typically ethanol or methanol)
UV-Vis spectroscopy software
Procedure:

Preparation of Standard Solutions:

Prepare a series of standard solutions of resveratrol with known concentrations. These standards will be used to create a calibration curve.
Sample Preparation:

Extract or prepare sample containing resveratrol. If the sample is a solid, you may need to extract the resveratrol using an appropriate solvent (eg, ethanol or methanol). Ensure that the sample is properly homogenized and filtered if necessary.
Blank Solution:

Prepare a blank solution using the same solvent used for the standards and sample. This blank will be used to zero the spectrophotometer.
Instrument Setup:

Turn on the UV-Vis spectrophotometer and allow it to warm up.
Set the wavelength to the appropriate range for resveratrol absorption, which is typically around 306-308 nm.
Calibrate the instrument using the blank solution.
Measurement:

Measure the absorbance of the blank solution at the chosen wavelength to zero the instrument.
Measure the absorbance of each standard solution and sample at the same wavelength.
Calibration Curve:

Plot a calibration curve with absorbance (y-axis) against the concentration of resveratrol standards (x-axis). The curve should be linear.
Use this calibration curve to determine the concentration of resveratrol in sample based on its absorbance.
Calculations:

Calculate the resveratrol content in sample using the calibration curve equation.

insert_drive_file Lab Report

Select a tab and click View to open the report.

timeline Service Steps

Step Procedure Expected Result
1

50...

check_circle_outline

1000µg/ml concentration of standard solution.

2

The standard...

check_circle_outline

Appropriate concentrations of Resveratrol solution within the linearity range

3

The solution...

check_circle_outline

Obtaining the value of maximum absorbance at 325 nm wavelength.

4

The...

check_circle_outline

Appropriate concentration of the tested sample within the linearity range.

5

The resveratrol content...

check_circle_outline

The value of Resveratrol content in the formulation(ug/ml) .

You will receive a report for the Concentration of Resveratrol (ug/ml) fields when we provide this service

Cart

No products

Subtotal: 0.00
Total 0.00 THB
UV-VIS Resveratrol Content Measurement

UV-VIS Resveratrol Content Measurement

Measuring the resveratrol content in a sample using UV-Vis (Ultraviolet-Visible) spectroscopy is a common and reliable analytical technique. Resveratrol is a natural compound found in grapes, red wine, and some other plants, known for its potential health benefits. UV-Vis spectroscopy works based on the principle that molecules absorb light at specific wavelengths, and this absorption can be used to quantify the concentration of a substance in a sample.

Materials and Equipment:

UV-Vis spectrophotometer
Resveratrol standard solution (of known concentration)
Sample containing resveratrol
Appropriate cuvettes or glass vials
Solvents (typically ethanol or methanol)
UV-Vis spectroscopy software
Procedure:

Preparation of Standard Solutions:

Prepare a series of standard solutions of resveratrol with known concentrations. These standards will be used to create a calibration curve.
Sample Preparation:

Extract or prepare sample containing resveratrol. If the sample is a solid, you may need to extract the resveratrol using an appropriate solvent (eg, ethanol or methanol). Ensure that the sample is properly homogenized and filtered if necessary.
Blank Solution:

Prepare a blank solution using the same solvent used for the standards and sample. This blank will be used to zero the spectrophotometer.
Instrument Setup:

Turn on the UV-Vis spectrophotometer and allow it to warm up.
Set the wavelength to the appropriate range for resveratrol absorption, which is typically around 306-308 nm.
Calibrate the instrument using the blank solution.
Measurement:

Measure the absorbance of the blank solution at the chosen wavelength to zero the instrument.
Measure the absorbance of each standard solution and sample at the same wavelength.
Calibration Curve:

Plot a calibration curve with absorbance (y-axis) against the concentration of resveratrol standards (x-axis). The curve should be linear.
Use this calibration curve to determine the concentration of resveratrol in sample based on its absorbance.
Calculations:

Calculate the resveratrol content in sample using the calibration curve equation.

Mechanism -
Appearance -
Longevity -
Strength -
Storage -
Shelf Life -
Allergen(s) -
Dosage (Range) -
Dosage (Per Day) -
Mix Method -
Heat Resistance -
Stable in pH range -
Solubility -
Product Types -
INCI -
Service Steps
Step Procedure Expected Result
1

50...

1000µg/ml concentration of standard solution.

2

The standard...

Appropriate concentrations of Resveratrol solution within the linearity range

3

The solution...

Obtaining the value of maximum absorbance at 325 nm wavelength.

4

The...

Appropriate concentration of the tested sample within the linearity range.

5

The resveratrol content...

The value of Resveratrol content in the formulation(ug/ml) .